TechnologyInside Aethera
Main site
  1. 00The plant
  2. 01AetheraFlow
  3. 02AetheraCore
  4. 03AetheraRegen
  5. 04AetheraStack
  6. 05AetheraBio
  7. 06AetheraSplit
  8. 07Edge data centre
  9. 08AetheraMind
  10. 09Products

Your moleculeIn the flue gas, leaving the stack

Aethera at a host plantNot to scale

00The journey

Follow one molecule of CO2 through Aethera.

From the stack of an industrial plant to a finished product, in nine stops. Scroll to travel through every module, the edge data centre and AetheraMind. Switch to Engineering at the top for the technical detail.

00.1

The host site

Cement, steel, refining, waste-to-energy. Any plant that burns or processes carbon sends a steady stream of flue gas up its stack. That gas is our raw material.

EngineeringTypical CO2 content of flue gas ranges from 3–5% for gas turbines to 15–30% for cement kilns.

00.2

A tie-in, not a rebuild

A duct taps the flue gas before it reaches the stack. The plant keeps running as before, and Aethera works alongside it.

EngineeringTie-in downstream of the plant’s own dust and emission controls, as a slipstream or full flow depending on size. A second tie-in brings waste heat for regeneration.

00.3

Six process modules

Each module is a 40-foot container with one job. The gas moves through them in order: intake, capture, release, compression, conversion, products.

00.4

The digital layer

An edge data centre on site runs the plant in real time. AetheraMind, the software, learns across every Aethera system at once.

00.5

Products out

At the end of the line come fuels, chemicals and materials, or clean, compressed CO2 for storage. The mix is chosen for each site.

M1 AetheraFlow, long sectionNot to scale

01M1Intake

AetheraFlow

Flue gas is hot, dusty and wet. AetheraFlow turns it into a clean, steady stream that the capture cassette can work with.

01.1

Draw

Centrifugal fans pull gas from the tie-in at a steady rate, whatever the plant upstream is doing.

EngineeringVariable-speed drives hold flow and pressure constant. An isolation damper lets the gas go straight to the stack at any moment, so the host plant is never at risk.

01.2

Filter

Dust and fine particles are caught before they can reach the sorbent. HEPA-grade filters take out the finest fraction.

EngineeringStaged filtration, coarse first and HEPA-grade last. Pressure drop across each stage is logged, so filters are changed on condition, not on a calendar.

01.3

Condition

Heat exchangers bring the gas down to the temperature the cassette works best at. Water that condenses out is drained away.

EngineeringGas-to-water heat exchange. Heat recovered here can be routed to the regeneration loop where temperatures allow. Condensate is collected and treated.

01.4

Measure

Before the gas moves on, analysers read what it contains, so the next module knows exactly what is coming.

EngineeringInline analysis of CO2, O2, H2O, NOx and SOx, plus flow, temperature and pressure. Readings stream continuously to the edge data centre.

Module sheet

In
Flue gas from the host plant
Out
Filtered, cooled gas to AetheraCore
Main equipment
Isolation damper, staged filters (HEPA-grade), centrifugal fans, heat exchangers, gas analysers
Measured
Composition, flow, temperature, pressure drop
Typical feed
CO2 content of flue gas: cement kilns 15–30%, waste-to-energy 8–12%, gas turbines 3–5% (industry ranges)
M2 AetheraCore, long section and detailsNot to scale

02M2Capture

AetheraCore

The heart of Aethera. The gas flows through cassettes of three stacked metal-organic frameworks, and the CO2 stays behind.

02.1

Cassettes in a rack

AetheraCore holds racks of identical cassettes, slotted in like drawers. A worn cassette is swapped, not repaired.

EngineeringCassettes are the wear part of the system and are renewed on a schedule. Design target, more than 10,000 cycles per cassette.

02.2

Beds take turns

While one bed captures, the other is being emptied by AetheraRegen. Valves switch them over, so capture never stops.

EngineeringTwo or more beds in parallel, cycled between adsorption and regeneration. The switch point is set by measurement, not by a fixed timer.

02.3

Layer 1, the guard

The first framework takes the heat cycling, the moisture and the acid gases, NOx and SOx, so the inner layers last.

EngineeringA sacrificial, robust framework that protects the more selective layers behind it.

02.4

Layer 2, the moisture shield

A water-repellent framework keeps humidity away from the core, where it would compete with CO2.

EngineeringHydrophobic framework. Water is the main competitor for adsorption sites in most sorbents.

02.5

Layer 3, the core

A high-capacity framework holds CO2 in its pores. Nitrogen and oxygen pass straight through and leave.

EngineeringPhysical adsorption, not amine chemistry. The binding is weaker than a chemical bond, which is why it releases at 80–120 °C. We do not disclose which three frameworks we use.

02.6

Breakthrough

When a bed is nearly full, CO2 starts to slip through. Sensors at the outlet see it, and the bed switches to release.

EngineeringOutlet analysers trace the breakthrough curve in real time. Switching early keeps capture above the design target of more than 92%.

Module sheet

In
Clean gas from AetheraFlow
Out
CO2-lean gas to the stack; loaded beds to regeneration
Sorbent
Three MOFs in one dedicated cassette
Design targets
More than 92% capture, more than 10,000 cycles per cassette
Control
Valve switching on breakthrough measurement
M3 AetheraRegen, heat loop and bedsNot to scale

03M3Release

AetheraRegen

Captured CO2 has to come out again. AetheraRegen does it with heat the host plant already throws away.

03.1

Waste heat in

A closed loop picks up low-grade heat from the host plant, at 80 to 120 °C, heat that would otherwise be lost.

EngineeringPossible sources include process cooling water, condensate and heat recovered from flue gas. The loop is separated from the plant by plate heat exchangers.

03.2

Warm the bed

The loop warms a loaded bed. As the framework warms up, it holds less CO2 and lets it go.

EngineeringTemperature swing adsorption. Capacity falls with temperature, so a modest temperature rise releases most of the captured CO2.

03.3

Collect

The released CO2 leaves the bed as a concentrated stream and is sent on for compression.

EngineeringLow-pressure product header to AetheraStack. Moisture carried over is knocked out before compression.

03.4

Cool and repeat

The bed is cooled back down and returns to capture. Heat moves between beds wherever possible, so less is needed from outside.

EngineeringHeat recovery between beds lowers net energy use. Design target for the whole capture cycle, about 1.8 GJ per tonne of CO2.

Module sheet

Heat source
Site waste heat, 80–120 °C
Method
Temperature swing adsorption (TSA)
Out
Concentrated CO2 to AetheraStack
Design target
About 1.8 GJ per tonne, against 2.5+ GJ for amine capture
M4 AetheraStack, compression trainNot to scale

04M4Compression

AetheraStack

The released CO2 is still a low-pressure gas. AetheraStack compresses it, dries it and polishes it to more than 99.9% purity.

04.1

Compress in stages

Several compressor stages raise the pressure step by step, up to 150 bar.

EngineeringMulti-stage compression with cooling between stages. Full pressure for transport and storage; a lower pressure where the gas goes straight to conversion.

04.2

Cool between stages

Gas heats up when it is squeezed. Coolers between the stages bring it back down, and water condenses out.

EngineeringIntercoolers and knock-out drums after each stage remove free water, which protects the next stage.

04.3

Dry and polish

A final drying step takes out the last moisture and lifts the stream above 99.9% CO2.

EngineeringDehydration to transport specification. Purity is confirmed by inline analysers before the gas leaves the module.

04.4

Recover energy

Piezoelectric harvesters on the compressors and pressure lines turn vibration and pressure pulses into electricity.

EngineeringRecovered energy powers sensors without cables and feeds back into the system. To be validated in the pilots.

04.5

Two ways out

The compressed CO2 goes either to AetheraBio for conversion, or off site for transport and storage.

EngineeringThe split is set by configuration. A capture-only site ends here.

Module sheet

In
Concentrated CO2 from AetheraRegen
Out
More than 99.9% CO2, up to 150 bar
Main equipment
Compressor stages, intercoolers, knock-out drums, dryer, analysers, piezo harvesters
Goes to
AetheraBio, or transport and storage
M5 AetheraBio, staged reactorNot to scale

05M5Conversion

AetheraBio

Here CO2 stops being a gas to get rid of and becomes a raw material. A staged reactor uses biology first and chemistry second.

05.1

Dissolve

Purified CO2 is bubbled into the reactor liquid, where it dissolves and becomes food.

EngineeringGas transfer into the liquid is a key design variable, set by bubble size, pressure and mixing.

05.2

Stage 1, microorganisms

Microorganisms take in the dissolved CO2 and, powered by renewable energy, turn it into small organic building blocks.

EngineeringOrganisms are selected per product route. Temperature, pH and cell density are measured continuously.

05.3

Stage 2, chains

The building blocks are joined into longer carbon chains, the backbone of fuels, plastics and chemicals.

05.4

Stage 3, catalysts

Catalysts reshape the chains into the target product. Which product is chosen for each site.

EngineeringBioconversion plus catalytic upgrading, configurable per output.

05.5

A closed loop

Water, nutrients and unused CO2 go back to the start. The mixture moves on to AetheraSplit.

Module sheet

In
CO2 from AetheraStack, renewable energy, water
Out
Product mixture to AetheraSplit
Method
Bioconversion plus catalytic upgrading, configurable per output
Measured
Temperature, pH, cell density, gas uptake
M6 AetheraSplit, separation and storageNot to scale

06M6Products

AetheraSplit

The reactor makes a mixture. AetheraSplit separates it into products a buyer can use, and sends everything else back.

06.1

Separate

In a column, the mixture is heated. Lighter products rise to the top, heavier ones stay low, and each is drawn off at its own height.

EngineeringSeparation by boiling point, with membranes where a product calls for it. A condenser at the top and a reboiler at the bottom drive the column.

06.2

Purify

Each product stream is cleaned to the specification its buyers expect.

EngineeringPurity is measured on every product line before storage.

06.3

Send back

Water and unused CO2 are returned to AetheraBio.

06.4

Store and ship

Products are stored on site and leave by truck, rail or ship, like any other chemical.

EngineeringMetered product tanks, so every tonne sold is traceable to the carbon captured.

Module sheet

In
Product mixture from AetheraBio
Out
Finished products to storage and buyers
Returns
Water and unused CO2 to AetheraBio
Main equipment
Separation column, condenser, reboiler, membranes, product tanks
Edge data centre, 20-foot containerNot to scale

07DCCompute

Edge data centre

Every Aethera system ships with its own small data centre, in its own container. It runs the plant in real time and keeps the data on site.

07.1

Sensors everywhere

Every module reports gas, heat, pressure, vibration and, in AetheraBio, biology. A constant stream of readings flows in.

07.2

Control in real time

Control runs locally, so valves, fans and heaters respond at once, without waiting on a connection to the outside world.

EngineeringDeterministic control loops on site. The plant keeps running safely if the external link goes down.

07.3

AI on site

Trained models run right here, tuning each cycle, predicting when a cassette needs renewing and flagging anything unusual.

07.4

Secure by design

Process data is stored and protected on site. What AetheraMind needs for fleet learning is sent on, encrypted.

EngineeringContainerised compute with its own power conditioning and cooling.

Module sheet

Form
Its own 20-foot container, shipped with every system
Does
Real-time control, local AI, data storage
Links to
Every process module, and AetheraMind
AetheraMind, the digital moduleNot to scale

08AIIntelligence

AetheraMind

The one module you cannot touch. AetheraMind is the software that runs every Aethera plant and learns from all of them at once.

08.1

A digital twin of every plant

Each site has a live digital copy, fed by its edge data centre. A change can be tested on the twin before it touches the real plant.

08.2

Learning across the fleet

What one site learns about a sorbent, a gas or a season is shared with every other site. The tenth plant starts smarter than the first.

08.3

Predict, not repair

Models watch fans, compressors and cassettes for the first signs of wear, so maintenance happens before anything breaks.

08.4

Verified carbon records

Every tonne captured and converted is measured and logged, to the standard needed for carbon credits.

EngineeringMRV-grade records of capture, conversion and products.

Module sheet

Form
Software, running on site and across the fleet
Does
Plant control, optimisation, predictive maintenance, MRV records
Data
Kept and owned by NorthShield

09Products

Where the carbon ends up.

The same plant can end in very different places. Pick a product to see its route through the modules, what it is used for and how long the carbon stays out of the air.

Chemicals and fuels

Bulk and strategic

Specialty carbon

Capture only

FlowCoreRegenStackBioSplit
Where the carbon goes
How long it stays
Short cycleProcess inputYearsLong-livedPermanent
Indicative market price

Per 100 tonnes of CO2 in the flue gas

To productsFuels, chemicals and materials, through AetheraBio and AetheraSplit.
Or to storageCompressed in AetheraStack and sent to a permanent store.
The mixSet for each site during engineering, from local demand, energy and buyers.

Capture figure is a design target, to be validated in the 2027 pilots. Prices are indicative market ranges, not NorthShield offers.

That is Aethera, end to end.

Six containers, one data centre and one piece of software, turning a cost into products, data and revenue.